N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)


  • Positive Focal Length and Near Best Form for Infinite Conjugate Applications
  • Many Thorlabs Lenses Available in Zemax Catalog

LA1740-B

(Ø75 mm)

LA1401-B

(Ø2")

LA1274-B

(Ø30 mm)

LA1951-B

(Ø1")

LA1252-B

(Ø25 mm)

LA1859-B

(Ø18 mm)

LA1540-B

(Ø1/2")

LA1576-B

(Ø9 mm)

LA1116-B

(Ø6 mm)

Lens Kits
Available

LA1039-B

(Ø3 mm)

LA1024-B

(Ø2 mm)

LA1385-B

(Ø1.5")

Related Items


Please Wait
Common Specifications
Diameters 2 mm and 3 mm 6 mm, 9 mm, 1/2", 18 mm, 25 mm, 1", 30 mm, 1.5", 2", and 75 mm
Lens Shape Plano-Convex
Substrate Material N-BK7 (Grade A)a
AR Coating Range 650 - 1050 nm (-B Coating)
Reflectanceb over Coating
Range (Avg.) @ 0° AOI
<0.5%
Design Wavelength 587.6 nmc
Index of Refraction 1.515d
Surface Flatness
(Plano Side)
λ/2d
Spherical Surface Powere
(Convex Side)
3λ/2d
Surface Irregularity
(Peak to Valley)
λ/4d
Surface Quality 60-40 Scratch-Dig 40-20 Scratch-Dig
Thickness Tolerance ±0.03 mm ±0.1 mm
Diameter Tolerance +0.00 / -0.02 mm +0.0 / -0.1 mm
Centration ≤5 arcmin <3 arcmin
Damage Thresholdf 7.5 J/cm2
(810 nm, 10 ns, 10 Hz, Ø0.144 mm)
Abbe Number vd = 64.17
Clear Aperture >90% of Diameterg
Focal Length Tolerance ±1%
  • Click Link for Detailed Specifications on the Substrate
  • Per Surface
  • Ø25 mm lenses have a design wavelength of 632.8 nm.
  • At 633 nm
  • Much like surface flatness for flat optics, spherical surface power is a measure of the deviation between the surface of the curved optic and a calibrated reference gauge, typically for a 633 nm source, unless otherwise stated. This specification is also commonly referred to as surface fit.
  • Limited by the Antireflection Coating; Refer to the Damage Thresholds Tab for Details
  • The LA1254-B, LA1258-B, and LA1259-B lenses have a clear aperture equal to 90% of the diameter.
Zemax Files
Click on the red Document icon next to the item numbers below to access the Zemax file download. Our entire Zemax Catalog is also available.
Optic Cleaning Tutorial

Features

  • Material: N-BK7
  • AR-Coated for the 650 - 1050 nm Range
  • Focal Lengths Available from 4 to 2500 mm

These Plano-Convex Lenses are fabricated from RoHS-compliant N-BK7 glass and feature an antireflection coating for the 650 nm to 1050 nm range. N-BK7 is typically chosen whenever the additional benefits of UV fused silica (i.e., good transmission further into the UV and a lower coefficient of thermal expansion) are not necessary. These lenses have a positive focal length and near-best-form shape for infinite and finite conjugate applications.

Plano-convex lenses can focus a collimated beam or collimate light from a point source. To minimize the introduction of spherical aberration, a collimated light source should be incident on the curved surface of the lens when being focused and a point light source should be incident on the planar surface when being collimated.

The focal length of each lens can be calculated using a simplified thick lens equation:

f = R/(n-1),

where n is the index of refraction and R is the radius of curvature of the lens surface. These lenses are fabricated from N-BK7, which has an Abbe Number of 64.17; this value is an indicator of the dispersion.

These N-BK7 Plano-Convex lenses are available uncoated or with one of five antireflection coatings (-A, -AB, -B, -C, or -D), which reduces the amount of light reflected from each surface of the lens (see the Selection Guide table below for links to each coating option). Since approximately 4% of the incident light is reflected at each surface of an uncoated substrate, the application of an AR coating improves transmission, which is important in low-light applications, and prevents the undesirable effects (e.g., ghost images) associated with multiple reflections. Having optics that are AR coated on both surfaces is particularly desirable for applications utilizing multiple optical elements. Please see the Graphs tab for additional coating information.

Thorlabs offers fixed lens mounts that can be used for mounting the lenses sold here. For mounting high-curvature lenses in select sizes, extra-thick retaining rings with SM05 (0.535"-40), SM1 (1.035"-40), or SM2 (2.035"-40) threading are available that provide extra clearance for spanner wrenches (see the Lens Mounting Guide tab for more information).

N-BK7 lens kits are also available. Please click here for information.

N-BK7 Plano-Convex Lens Selection Guide
Unmounted Lenses Mounted Lenses
Uncoated Uncoated
-A Coating (350 - 700 nm) -A Coating (350 - 700 nm)
-AB Coating (400 - 1100 nm) -AB Coating (400 - 1100 nm)
-B Coating (650 - 1050 nm) -B Coating (650 - 1050 nm)
-C Coating (1050 - 1700 nm) -C Coating (1050 - 1700 nm)
-D Coating (1650 - 3000 nm) -

Custom Coatings are also available. Please contact Tech Sales for a quote.

Optical Coatings and Substrates
Lens Tutorial

Below is the transmission curve for N-BK7, a RoHS-compliant form of BK7. Total Transmission is shown for a 10 mm thick, uncoated sample and includes surface reflections. Each of these unmounted N-BK7 plano-convex lenses can be ordered uncoated or with one of the following broadband AR coatings: 350 - 700 nm (designated with -A), 400 - 1100 nm (-AB), 650 - 1050 nm (-B), or 1050 - 1700 nm (-C) or 1.65 - 3.0 µm (-D).

These high-performance multilayer AR coatings have an average reflectance of less than 0.5% (per surface) across the specified wavelength ranges (except for the -AB and -D coatings, which provide <1.0% average reflectance) and provide good performance for angles of incidence (AOI) between 0° and 30° (0.5 NA). For optics intended to be used at large incident angles, consider using a custom coating optimized at a 45° angle of incidence; this custom coating is effective from 25° to 52°. The plot shown below indicates the performance of the standard coatings in this family as a function of wavelength. Broadband coatings have a typical absorption of 0.25%, which is not shown in the reflectance plots.

N-BK7 Transmittance
Click to Enlarge

Click Here for Raw Data
B AR Coating
Click to Enlarge

Click Here for Raw Data
The blue shaded region indicates the specified 650 - 1050 nm wavelength range for optimum performance.

Thorlabs' Standard Broadband Antireflection Coatings

Key Quality Control Equipment
  • TriOptics OptiSpheric
  • Zygo GPI-XP/D Interferometer
  • PerkinElmer Lambda 1050 Spectrophotometer
  • Agilent Cary 5000 Spectrophotometer
Click to Enlarge
A Thorlabs technician measuring the irregularity of one of our singlets using a Zygo GPI-XP/D Interferometer.

Introduction
Thorlabs has a series of quality control procedures in order to ensure our singlets meet our standards and specifications. This starts with in-process inspections of the lens’ imaging capabilities and ends with a final inspection of surface quality and dimensions. Specifications for particular products can be found in their linked documentation by clicking the  symbol. This tab will take you through the general process used to check for quality.

Singlet Quality Practices
In-process inspection begins once the singlet has been shaped to specifications. Focal length, surface irregularity, and surface power are checked, following sampling plan Level VI given in MIL-PRF-13830B (see below). These three specifications are imperative for proper imaging. Surface irregularity of parts is kept to below either a quarter wavelength or a half wavelength at 633 nm, depending on the material of the singlet. Below is a graph of over 200 batches of singlets with irregularity data of both their front and back sides.

At this point, some uncoated singlets will proceed to final inspection, while others will receive an antireflective (AR) coating. The application of optical coatings has its own in-process inspections. To ensure the AR coating is applied properly, we verify both reflectance and transmission performance by scanning witness pieces using spectrophotometry; the material of these 2 mm thick witness samples matches the other parts in the run. For reflectance verification, we use at least one witness sample for each coating run. Transmitting optics receive two AR coatings, one on each surface, so for the verification of transmission, we use one witness sample that is also coated on both of its sides. Large runs use multiple witness samples to ensure the uniformity across the deposition chamber. By testing coating performance during every run, variance over time is kept low. To see how coatings vary, see the table below.

Final inspection of both uncoated and AR-coated singlets includes a batch check of diameter and thickness and a 100% visual check to ensure that the surface quality, chamfer, and clear aperture meet our published specifications. While surface quality is cosmetic to a degree, scratches, digs, and other inclusions in the surface of a part can increase the chances of damage to the singlet when used with high-power sources. These inspections are done in a clean, dark room under lighting that meets the requirements of MIL-PRF-13830B. Inspection under a single light source in a dark room allows for inconsistencies in the glass to be located without being obscured by glare or reflections.

MIL-PRF-13830B: Performance Specifications for Optical Components
MIL-PRF-13830B is a document created by the U.S. Army Armament Research, Development and Engineering Center's Defense Quality and Standardization Office for the specifications covering how finished optical components should be manufactured, assembled, and inspected. While primarily for use in letting the military dictate how products they use can be incorporated into their equipment, these standards have been adopted by many optics manufacturers. To download a copy of the full document, click here.

-A Coating
350 nm to 700 nm
-B Coating
650 nm to 1050 nm
-C Coating
1050 nm to 1700 nm
Singlet
Irregularity
Coating Variance:
Transmission

Click to Enlarge

Click to Enlarge

Click to Enlarge

Click to Enlarge
Coating Variance:
Reflectance

Click to Enlarge

Click to Enlarge

Click to Enlarge

Disclaimer: The coated transmission data presented here are of 2 mm thick witness samples of N-BK7 or equivalent glass, and all the data here are typical. Some variations in performance data will occur from lot to lot. Please contact Technical Support with any questions regarding the use or reliability of these data.

BK7 Index of Refraction
Click here for raw data.
In the thick lens equation, use the index of refraction for N-BK7 at the wavelength of interest to approximate the wavelength-dependent focal length of any of the plano-convex lenses.

The focal length of a thick spherical lens can be calculated using the thick lens equation below. In this expression, nl is the index of refraction of the lens, R1 and R2 are the radii of curvature for surfaces 1 and 2, respectively, and d is the center thickness of the lens.

thick lens equation

When using the thick lens equation to calculate the focal length of a plano-convex lens, R1=∞ and R2=-R. Note that the minus sign in front of R is due to the sign convention used when deriving the thick lens equations and values of R are reported in the Specs tab as well as on the mechanical drawing for each lens. Therefore, via substitution, the thick lens equation becomes

simple thick lens equation

The focal length of the lens calculated using the simplified thick lens equation directly above is the distance between the second (back) principle plane (H") and the position at which a collimated beam incident on the curved surface of the plano-convex is focused. The principle plane positions of a thick lens can be calculated with the following equations:

principal plane equation one and Principal plane equation two

However, as with the thick lens equation, H' simplifies to zero and H" simplifies to

Principal plane two simple

when used to calculate the principal plane locations of plano-convex lenses. fb is the back focal length of the lens, which is often referred to as the working distance of the lens.

Damage Threshold Specifications
Coating Designation
(Item # Suffix)
Damage Threshold
-B 7.5 J/cm2 (810 nm, 10 ns, 10 Hz, Ø0.144 mm)

Damage Threshold Data for Thorlabs' B-Coated N-BK7 Singlet Lenses

The specifications to the right are measured data for Thorlabs' B-coated N-BK7 singlet lenses. Damage threshold specifications are constant for all B-coated N-BK7 singlet lenses, regardless of the size or the focal length of the lens.

 

Laser Induced Damage Threshold Tutorial

The following is a general overview of how laser induced damage thresholds are measured and how the values may be utilized in determining the appropriateness of an optic for a given application. When choosing optics, it is important to understand the Laser Induced Damage Threshold (LIDT) of the optics being used. The LIDT for an optic greatly depends on the type of laser you are using. Continuous wave (CW) lasers typically cause damage from thermal effects (absorption either in the coating or in the substrate). Pulsed lasers, on the other hand, often strip electrons from the lattice structure of an optic before causing thermal damage. Note that the guideline presented here assumes room temperature operation and optics in new condition (i.e., within scratch-dig spec, surface free of contamination, etc.). Because dust or other particles on the surface of an optic can cause damage at lower thresholds, we recommend keeping surfaces clean and free of debris. For more information on cleaning optics, please see our Optics Cleaning tutorial.

Testing Method

Thorlabs' LIDT testing is done in compliance with ISO/DIS 11254 and ISO 21254 specifications.

First, a low-power/energy beam is directed to the optic under test. The optic is exposed in 10 locations to this laser beam for 30 seconds (CW) or for a number of pulses (pulse repetition frequency specified). After exposure, the optic is examined by a microscope (~100X magnification) for any visible damage. The number of locations that are damaged at a particular power/energy level is recorded. Next, the power/energy is either increased or decreased and the optic is exposed at 10 new locations. This process is repeated until damage is observed. The damage threshold is then assigned to be the highest power/energy that the optic can withstand without causing damage. A histogram such as that below represents the testing of one BB1-E02 mirror.

LIDT metallic mirror
The photograph above is a protected aluminum-coated mirror after LIDT testing. In this particular test, it handled 0.43 J/cm2 (1064 nm, 10 ns pulse, 10 Hz, Ø1.000 mm) before damage.
LIDT BB1-E02
Example Test Data
Fluence # of Tested Locations Locations with Damage Locations Without Damage
1.50 J/cm2 10 0 10
1.75 J/cm2 10 0 10
2.00 J/cm2 10 0 10
2.25 J/cm2 10 1 9
3.00 J/cm2 10 1 9
5.00 J/cm2 10 9 1

According to the test, the damage threshold of the mirror was 2.00 J/cm2 (532 nm, 10 ns pulse, 10 Hz, Ø0.803 mm). Please keep in mind that these tests are performed on clean optics, as dirt and contamination can significantly lower the damage threshold of a component. While the test results are only representative of one coating run, Thorlabs specifies damage threshold values that account for coating variances.

Continuous Wave and Long-Pulse Lasers

When an optic is damaged by a continuous wave (CW) laser, it is usually due to the melting of the surface as a result of absorbing the laser's energy or damage to the optical coating (antireflection) [1]. Pulsed lasers with pulse lengths longer than 1 µs can be treated as CW lasers for LIDT discussions.

When pulse lengths are between 1 ns and 1 µs, laser-induced damage can occur either because of absorption or a dielectric breakdown (therefore, a user must check both CW and pulsed LIDT). Absorption is either due to an intrinsic property of the optic or due to surface irregularities; thus LIDT values are only valid for optics meeting or exceeding the surface quality specifications given by a manufacturer. While many optics can handle high power CW lasers, cemented (e.g., achromatic doublets) or highly absorptive (e.g., ND filters) optics tend to have lower CW damage thresholds. These lower thresholds are due to absorption or scattering in the cement or metal coating.

Linear Power Density Scaling

LIDT in linear power density vs. pulse length and spot size. For long pulses to CW, linear power density becomes a constant with spot size. This graph was obtained from [1].

Intensity Distribution

Pulsed lasers with high pulse repetition frequencies (PRF) may behave similarly to CW beams. Unfortunately, this is highly dependent on factors such as absorption and thermal diffusivity, so there is no reliable method for determining when a high PRF laser will damage an optic due to thermal effects. For beams with a high PRF both the average and peak powers must be compared to the equivalent CW power. Additionally, for highly transparent materials, there is little to no drop in the LIDT with increasing PRF.

In order to use the specified CW damage threshold of an optic, it is necessary to know the following:

  1. Wavelength of your laser
  2. Beam diameter of your beam (1/e2)
  3. Approximate intensity profile of your beam (e.g., Gaussian)
  4. Linear power density of your beam (total power divided by 1/e2 beam diameter)

Thorlabs expresses LIDT for CW lasers as a linear power density measured in W/cm. In this regime, the LIDT given as a linear power density can be applied to any beam diameter; one does not need to compute an adjusted LIDT to adjust for changes in spot size, as demonstrated by the graph to the right. Average linear power density can be calculated using the equation below. 

The calculation above assumes a uniform beam intensity profile. You must now consider hotspots in the beam or other non-uniform intensity profiles and roughly calculate a maximum power density. For reference, a Gaussian beam typically has a maximum power density that is twice that of the uniform beam (see lower right).

Now compare the maximum power density to that which is specified as the LIDT for the optic. If the optic was tested at a wavelength other than your operating wavelength, the damage threshold must be scaled appropriately. A good rule of thumb is that the damage threshold has a linear relationship with wavelength such that as you move to shorter wavelengths, the damage threshold decreases (i.e., a LIDT of 10 W/cm at 1310 nm scales to 5 W/cm at 655 nm):

CW Wavelength Scaling

While this rule of thumb provides a general trend, it is not a quantitative analysis of LIDT vs wavelength. In CW applications, for instance, damage scales more strongly with absorption in the coating and substrate, which does not necessarily scale well with wavelength. While the above procedure provides a good rule of thumb for LIDT values, please contact Tech Support if your wavelength is different from the specified LIDT wavelength. If your power density is less than the adjusted LIDT of the optic, then the optic should work for your application. 

Please note that we have a buffer built in between the specified damage thresholds online and the tests which we have done, which accommodates variation between batches. Upon request, we can provide individual test information and a testing certificate. The damage analysis will be carried out on a similar optic (customer's optic will not be damaged). Testing may result in additional costs or lead times. Contact Tech Support for more information.

Pulsed Lasers

As previously stated, pulsed lasers typically induce a different type of damage to the optic than CW lasers. Pulsed lasers often do not heat the optic enough to damage it; instead, pulsed lasers produce strong electric fields capable of inducing dielectric breakdown in the material. Unfortunately, it can be very difficult to compare the LIDT specification of an optic to your laser. There are multiple regimes in which a pulsed laser can damage an optic and this is based on the laser's pulse length. The highlighted columns in the table below outline the relevant pulse lengths for our specified LIDT values.

Pulses shorter than 10-9 s cannot be compared to our specified LIDT values with much reliability. In this ultra-short-pulse regime various mechanics, such as multiphoton-avalanche ionization, take over as the predominate damage mechanism [2]. In contrast, pulses between 10-7 s and 10-4 s may cause damage to an optic either because of dielectric breakdown or thermal effects. This means that both CW and pulsed damage thresholds must be compared to the laser beam to determine whether the optic is suitable for your application.

Pulse Duration t < 10-9 s 10-9 < t < 10-7 s 10-7 < t < 10-4 s t > 10-4 s
Damage Mechanism Avalanche Ionization Dielectric Breakdown Dielectric Breakdown or Thermal Thermal
Relevant Damage Specification No Comparison (See Above) Pulsed Pulsed and CW CW

When comparing an LIDT specified for a pulsed laser to your laser, it is essential to know the following:

Energy Density Scaling

LIDT in energy density vs. pulse length and spot size. For short pulses, energy density becomes a constant with spot size. This graph was obtained from [1].

  1. Wavelength of your laser
  2. Energy density of your beam (total energy divided by 1/e2 area)
  3. Pulse length of your laser
  4. Pulse repetition frequency (prf) of your laser
  5. Beam diameter of your laser (1/e2 )
  6. Approximate intensity profile of your beam (e.g., Gaussian)

The energy density of your beam should be calculated in terms of J/cm2. The graph to the right shows why expressing the LIDT as an energy density provides the best metric for short pulse sources. In this regime, the LIDT given as an energy density can be applied to any beam diameter; one does not need to compute an adjusted LIDT to adjust for changes in spot size. This calculation assumes a uniform beam intensity profile. You must now adjust this energy density to account for hotspots or other nonuniform intensity profiles and roughly calculate a maximum energy density. For reference a Gaussian beam typically has a maximum energy density that is twice that of the 1/e2 beam.

Now compare the maximum energy density to that which is specified as the LIDT for the optic. If the optic was tested at a wavelength other than your operating wavelength, the damage threshold must be scaled appropriately [3]. A good rule of thumb is that the damage threshold has an inverse square root relationship with wavelength such that as you move to shorter wavelengths, the damage threshold decreases (i.e., a LIDT of 1 J/cm2 at 1064 nm scales to 0.7 J/cm2 at 532 nm):

Pulse Wavelength Scaling

You now have a wavelength-adjusted energy density, which you will use in the following step.

Beam diameter is also important to know when comparing damage thresholds. While the LIDT, when expressed in units of J/cm², scales independently of spot size; large beam sizes are more likely to illuminate a larger number of defects which can lead to greater variances in the LIDT [4]. For data presented here, a <1 mm beam size was used to measure the LIDT. For beams sizes greater than 5 mm, the LIDT (J/cm2) will not scale independently of beam diameter due to the larger size beam exposing more defects.

The pulse length must now be compensated for. The longer the pulse duration, the more energy the optic can handle. For pulse widths between 1 - 100 ns, an approximation is as follows:

Pulse Length Scaling

Use this formula to calculate the Adjusted LIDT for an optic based on your pulse length. If your maximum energy density is less than this adjusted LIDT maximum energy density, then the optic should be suitable for your application. Keep in mind that this calculation is only used for pulses between 10-9 s and 10-7 s. For pulses between 10-7 s and 10-4 s, the CW LIDT must also be checked before deeming the optic appropriate for your application.

Please note that we have a buffer built in between the specified damage thresholds online and the tests which we have done, which accommodates variation between batches. Upon request, we can provide individual test information and a testing certificate. Contact Tech Support for more information.


[1] R. M. Wood, Optics and Laser Tech. 29, 517 (1998).
[2] Roger M. Wood, Laser-Induced Damage of Optical Materials (Institute of Physics Publishing, Philadelphia, PA, 2003).
[3] C. W. Carr et al., Phys. Rev. Lett. 91, 127402 (2003).
[4] N. Bloembergen, Appl. Opt. 12, 661 (1973).

In order to illustrate the process of determining whether a given laser system will damage an optic, a number of example calculations of laser induced damage threshold are given below. For assistance with performing similar calculations, we provide a spreadsheet calculator that can be downloaded by clicking the button to the right. To use the calculator, enter the specified LIDT value of the optic under consideration and the relevant parameters of your laser system in the green boxes. The spreadsheet will then calculate a linear power density for CW and pulsed systems, as well as an energy density value for pulsed systems. These values are used to calculate adjusted, scaled LIDT values for the optics based on accepted scaling laws. This calculator assumes a Gaussian beam profile, so a correction factor must be introduced for other beam shapes (uniform, etc.). The LIDT scaling laws are determined from empirical relationships; their accuracy is not guaranteed. Remember that absorption by optics or coatings can significantly reduce LIDT in some spectral regions. These LIDT values are not valid for ultrashort pulses less than one nanosecond in duration.

Intensity Distribution
A Gaussian beam profile has about twice the maximum intensity of a uniform beam profile.

CW Laser Example
Suppose that a CW laser system at 1319 nm produces a 0.5 W Gaussian beam that has a 1/e2 diameter of 10 mm. A naive calculation of the average linear power density of this beam would yield a value of 0.5 W/cm, given by the total power divided by the beam diameter:

CW Wavelength Scaling

However, the maximum power density of a Gaussian beam is about twice the maximum power density of a uniform beam, as shown in the graph to the right. Therefore, a more accurate determination of the maximum linear power density of the system is 1 W/cm.

An AC127-030-C achromatic doublet lens has a specified CW LIDT of 350 W/cm, as tested at 1550 nm. CW damage threshold values typically scale directly with the wavelength of the laser source, so this yields an adjusted LIDT value:

CW Wavelength Scaling

The adjusted LIDT value of 350 W/cm x (1319 nm / 1550 nm) = 298 W/cm is significantly higher than the calculated maximum linear power density of the laser system, so it would be safe to use this doublet lens for this application.

Pulsed Nanosecond Laser Example: Scaling for Different Pulse Durations
Suppose that a pulsed Nd:YAG laser system is frequency tripled to produce a 10 Hz output, consisting of 2 ns output pulses at 355 nm, each with 1 J of energy, in a Gaussian beam with a 1.9 cm beam diameter (1/e2). The average energy density of each pulse is found by dividing the pulse energy by the beam area:

Pulse Energy Density

As described above, the maximum energy density of a Gaussian beam is about twice the average energy density. So, the maximum energy density of this beam is ~0.7 J/cm2.

The energy density of the beam can be compared to the LIDT values of 1 J/cm2 and 3.5 J/cm2 for a BB1-E01 broadband dielectric mirror and an NB1-K08 Nd:YAG laser line mirror, respectively. Both of these LIDT values, while measured at 355 nm, were determined with a 10 ns pulsed laser at 10 Hz. Therefore, an adjustment must be applied for the shorter pulse duration of the system under consideration. As described on the previous tab, LIDT values in the nanosecond pulse regime scale with the square root of the laser pulse duration:

Pulse Length Scaling

This adjustment factor results in LIDT values of 0.45 J/cm2 for the BB1-E01 broadband mirror and 1.6 J/cm2 for the Nd:YAG laser line mirror, which are to be compared with the 0.7 J/cm2 maximum energy density of the beam. While the broadband mirror would likely be damaged by the laser, the more specialized laser line mirror is appropriate for use with this system.

Pulsed Nanosecond Laser Example: Scaling for Different Wavelengths
Suppose that a pulsed laser system emits 10 ns pulses at 2.5 Hz, each with 100 mJ of energy at 1064 nm in a 16 mm diameter beam (1/e2) that must be attenuated with a neutral density filter. For a Gaussian output, these specifications result in a maximum energy density of 0.1 J/cm2. The damage threshold of an NDUV10A Ø25 mm, OD 1.0, reflective neutral density filter is 0.05 J/cm2 for 10 ns pulses at 355 nm, while the damage threshold of the similar NE10A absorptive filter is 10 J/cm2 for 10 ns pulses at 532 nm. As described on the previous tab, the LIDT value of an optic scales with the square root of the wavelength in the nanosecond pulse regime:

Pulse Wavelength Scaling

This scaling gives adjusted LIDT values of 0.08 J/cm2 for the reflective filter and 14 J/cm2 for the absorptive filter. In this case, the absorptive filter is the best choice in order to avoid optical damage.

Pulsed Microsecond Laser Example
Consider a laser system that produces 1 µs pulses, each containing 150 µJ of energy at a repetition rate of 50 kHz, resulting in a relatively high duty cycle of 5%. This system falls somewhere between the regimes of CW and pulsed laser induced damage, and could potentially damage an optic by mechanisms associated with either regime. As a result, both CW and pulsed LIDT values must be compared to the properties of the laser system to ensure safe operation.

If this relatively long-pulse laser emits a Gaussian 12.7 mm diameter beam (1/e2) at 980 nm, then the resulting output has a linear power density of 5.9 W/cm and an energy density of 1.2 x 10-4 J/cm2 per pulse. This can be compared to the LIDT values for a WPQ10E-980 polymer zero-order quarter-wave plate, which are 5 W/cm for CW radiation at 810 nm and 5 J/cm2 for a 10 ns pulse at 810 nm. As before, the CW LIDT of the optic scales linearly with the laser wavelength, resulting in an adjusted CW value of 6 W/cm at 980 nm. On the other hand, the pulsed LIDT scales with the square root of the laser wavelength and the square root of the pulse duration, resulting in an adjusted value of 55 J/cm2 for a 1 µs pulse at 980 nm. The pulsed LIDT of the optic is significantly greater than the energy density of the laser pulse, so individual pulses will not damage the wave plate. However, the large average linear power density of the laser system may cause thermal damage to the optic, much like a high-power CW beam.

CXY1A in 30 mm Cage System
Click to Enlarge

CXY1A Translation Mount and
SM1 Lens Tube Mounted in a
30 mm Cage System
Threaded Mounting Adapter
Click to Enlarge

Ø1" Optic Mounted in a
ST1XY-S XY Translator

Click to Enlarge

LMR1 Fixed Mount with Ø1" Lens

Click to Enlarge

LM2XY Translating Mount with Ø2" Lens
Recommended Mounting Options for Thorlabs Lenses
Item # Mounts for Ø2 mm to Ø10 mm Optics
Imperial Metric
(Various) Fixed Lens Mounts and Mini-Series Fixed Lens Mounts for Small Optics, Ø5 mm to Ø10 mm
(Various) Small Optic Adapters for Use with Standard Fixed Lens Mounts, Ø2 mm to Ø10 mm
Item # Mounts for Ø1/2" (Ø12.7 mm) Optics
Imperial Metric
LMR05 LMR05/M Fixed Lens Mount for Ø1/2" Optics
MLH05 MLH05/M Mini-Series Fixed Lens Mount for Ø1/2" Optics
LM05XY LM05XY/M Translating Lens Mount for Ø1/2" Optics
SCP05 16 mm Cage System, XY Translation Mount for Ø1/2" Optics
(Various) Ø1/2" Lens Tubes,
Optional SM05RRC Retaining Ring for High-Curvature Lenses (See Below)
Item # Mounts for Ø1" (Ø25.4 mm) Optics
Imperial Metric
LMR1 LMR1/M Fixed Lens Mount for Ø1" Optics
LM1XY LM1XY/M Translating Lens Mount for Ø1" Optics
ST1XY-S ST1XY-S/M Translating Lens Mount with Micrometer Drives (Other Drives Available)
CXY1A 30 mm Cage System, XY Translation Mount for Ø1" Optics
(Various) Ø1" Lens Tubes,
Optional SM1RRC Retaining Ring for High-Curvature Lenses (See Below)
Item # Mount for Ø1.5" Optics
Imperial Metric
LMR1.5 LMR1.5/M Fixed Lens Mount for Ø1.5" Optics
(Various) Ø1.5" Lens Tubes,
Optional SM1.5RR Retaining Ring for Ø1.5" Lens Tubes and Mounts
Item # Mounts for Ø2" (Ø50.8 mm) Optics
Imperial Metric
LMR2 LMR2/M Fixed Lens Mount for Ø2" Optics
LM2XY LM2XY/M Translating Lens Mount for Ø2" Optics
CXY2 60 mm Cage System, XY Translation Mount for Ø2" Optics
(Various) Ø2" Lens Tubes,
Optional SM2RRC Retaining Ring for High-Curvature Lenses (See Below)
Item # Adjustable Optic Mounts
Imperial Metric
LH1 LH1/M Adjustable Mount for Ø0.28" (Ø7.1 mm) to Ø1.80" (Ø45.7 mm) Optics
LH2 LH2/M Adjustable Mount for Ø0.77" (Ø19.6 mm) to Ø2.28" (Ø57.9 mm) Optics
VG100 VG100/M Adjustable Clamp for Ø0.5" (Ø13 mm) to Ø3.5" (Ø89 mm) Optics
SCL03 SCL03/M Self-Centering Mount for Ø0.15" (Ø3.8 mm) to Ø1.77" (Ø45.0 mm) Optics
SCL04 SCL04/M Self-Centering Mount for Ø0.15" (Ø3.8 mm) to Ø3.00" (Ø76.2 mm) Optics
LH160C LH160C/M Adjustable Mount for 60 mm Cage Systems,
Ø0.50" (Ø13 mm) to Ø2.00" (Ø50.8 mm) Optics
SCL60CA SCL60C/M Self-Centering Mount for 60 mm Cage Systems,
Ø0.15" (Ø3.8 mm) to Ø1.77" (Ø45.0 mm) Optics

Mounting High-Curvature Optics

Thorlabs' retaining rings are used to secure unmounted optics within lens tubes or optic mounts. These rings are secured in position using a compatible spanner wrench. For flat or low-curvature optics, standard retaining rings manufactured from anodized aluminum are available from Ø5 mm to Ø4". For high-curvature optics, extra-thick retaining rings are available in Ø1/2", Ø1", and Ø2" sizes.

Extra-thick retaining rings offer several features that aid in mounting high-curvature optics such as aspheric lenses, short-focal-length plano-convex lenses, and condenser lenses. As shown in the animation to the right, the guide flange of the spanner wrench will collide with the surface of high-curvature lenses when using a standard retaining ring, potentially scratching the optic. This contact also creates a gap between the spanner wrench and retaining ring, preventing the ring from tightening correctly. Extra-thick retaining rings provide the necessary clearance for the spanner wrench to secure the lens without coming into contact with the optic surface.


Posted Comments:
user  (posted 2024-05-10 16:08:43.417)
It seems the picture for this product is not a 1" lens (or it at least doesn't look like any of the other 1" lenses).
jpolaris  (posted 2024-05-10 05:51:15.0)
Thank you for bringing this to our attention. It does appear that the incorrect image may have been used for LA1908-B.
Kristian Cvecek  (posted 2023-09-15 09:58:09.39)
As a mounting options for Ø75.0 mm lenses you suggest to use the LMR75(/M). However, we need a radially symmetric tube-like mount to integrate with other components. Would the SM3 tubes work also for this lens size?
Benjamin Lothschutz  (posted 2023-02-17 12:41:20.473)
Hello, What is the damage threshold of N-BK7 -b coating for CW lasers? I only see pulsed laser threshold posted. Looking for lens capable of 750W at 1" optic. Also looking at the UV fused silica line which appears to have a >82kW/cm (should be cm squared correct?). I have used the N-BK7 at 400W and under without issue. https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=6532 Wavelength 980nm Thanks,
cdolbashian  (posted 2023-04-13 10:25:57.0)
While we haven't tested the N-BK7 windows for CW damage at the time of posting, we do have similar test data for UVFS windows coated with -B coating. We have seen that the damage thresholds of these coatings for UVFS and N-BK7 is similar. For the UVFS windows, we found the damage to be 20 kW/cm (1070 nm, Ø0.974 mm). In this case, I would assume something similar for N-BK7. Furthermore, we have a description above in the "Damage Thresholds" and "LIDT calculations" tabs addressing the use of W/cm rather than W/cm^2.
Deepak Korhalkar  (posted 2022-11-26 16:00:29.343)
Hello Tech Support, We are considering N-BK7 OR UV Fused Silica, Plano Convex lenses of various diameters & EFLs for incorporation in our Medical Laser under development. Typical examples are #LA1131 ( N-BK7 )& #LA4036 (UV FS) Our laser pulses are of millisec duration ( 1 to 50 millisec approx. ) at 1064 nanometer. As per your tutorial on LIDT, we should be considering CW LIDT specification for the various coating options. I request you to kindly specify the same for following coating types - -B -C -1064 -YAG Your catalogue specifications mention LIDT for Pulsed laser only ( 10 nanosec.) but we need the same for CW operating regime for all the coting types mentioned above - for both N-BK7 & UV FS substrates. Kindly respond as early as possible so that we can select the right kind of Optics for our design. Thanking you in advance. Best Regards.
cdolbashian  (posted 2022-12-02 04:07:34.0)
Thank you for contacting Thorlabs. At the moment we have not yet tested these coated lenses for a CW damage threshold. It is not possible to achieve an accurate laser damage value by converting from pulsed energy density to CW power density since there are different damage mechanisms for pulsed and CW beams. I will reach out to you directly to discuss your application and advise on if these lenses will be suitable for your application.
Ekaterina Osipova  (posted 2022-10-08 18:09:34.25)
Is the lens coating just on one side or both?
ksosnowski  (posted 2022-10-10 12:45:44.0)
Hello Ekaterina, thanks for reaching out to Thorlabs. All of the lenses on this page are coated on both surfaces. If the optic does not have the same coating on both surfaces, our CAD will define the surfaces S1 and S2 the coating type for each.
abc124771  (posted 2018-11-16 02:06:01.29)
I'm using LA1951-B for collimation. Could you please specify its Numerical Aperture? Can NA be calculated from user side? How to calculate it?
nbayconich  (posted 2018-11-16 09:27:09.0)
Thank you for contacting Thorlabs. The numerical aperture of this lens will be about 0.45. The Numerical aperture is typically defined by NA = Ø/(2*f) where Ø is the clear aperture of the lens and f is your effective focal length.
james  (posted 2014-06-04 12:28:35.61)
I am having problems understanding the back focal length for plano convex lenses. It seems the number you give is with the lens reversed so the curved side is toward the focal point. How do I get the distance from the flat side of the lens to the focal point?
besembeson  (posted 2014-06-05 04:45:36.0)
A response from Bweh E at Thorlabs Newton-USA: Thanks for contacting Thorlabs. We actually have a Reference Drawing on the website that shows distances from various planes in the lens. The distance you are alluding to here is the back focal length, (fb). I will send you email with this reference drawing and point you to where you can find this on our website.
jjurado  (posted 2011-05-18 10:05:00.0)
Response from Javier at Thorlabs to 695359890: Dear Miss Zhang, thank you very much for contacting us with your request. We recommend using aspheric lenses for most applications that involve light collimation. We offer a variety of options, depending mainly on the desired focal length and operating wavelength. For operation at 785 nm, it would be best to use a lens with an anti-reflective coating in the 650-1050 nm range, or B coating. Please visit the link below for our current offerings: http://www.thorlabs.com/NewGroupPage9.cfm?ObjectGroup_ID=3811 I will contact you directly for further support.
695359890  (posted 2011-05-17 21:20:54.0)
Dear sir/madam: I want to buy a collimate len, which has the wavelength of 785nm,and has the AR for this wavelength, the f is about 10-30mm, I have not found such a len which is suitable for the above conditions, If can you give me some advices. Thank you very much! Miss zhang
jjurado  (posted 2011-02-23 14:44:00.0)
Response from Javier at Thorlabs to barbieri: Thank you for submitting your request. The damage threshold for our N-BK7 AR coated singlet lenses is in the neighborhood of 7.5 J/cm^2 (tested at 810 nm, 10 Hz PRF, 10 ns pulsewidth). We will post this information on the web shortly.
barbieri  (posted 2011-02-23 13:41:24.0)
I cannot seem to find damage threshold specifications for your spherical lenses. This information is critical when working with high-energy lasers. Can you please provide me with this information. Thanks.
klee  (posted 2009-09-03 11:13:24.0)
A response from Ken at Thorlabs to jorge: The typical damage threshold for our broadband AR coatings is 50W/cm^2 for CW.
jorge  (posted 2009-09-02 15:32:21.0)
I am working with a high power laser, power of 20W at 1064nm, so it is very important to know if the coating of the lenses is appropiate for such power. It would be very nice if you could include in the specifications of the lenses the damage threshold for each kind of coating. Best regards, Jorge A. Seman
Back to Top

Ø2.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1024-B 2.0 4.0 +250.0 2.1 1.0 0.7 3.34 Plano-Convex Lens Drawing
LA1026-B 2.0 6.0 +166.7 3.1 1.0 0.8 5.34
  • Suggested Fixed Lens Mount: LMR05(/M) or MLH05(/M) with an LMRA2 Glue-In Adapter for Ø2 mm Optics
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1024-B Support Documentation
LA1024-BN-BK7 Plano-Convex Lens, Ø2.0 mm, f = 4 mm, AR Coating: 650 - 1050 nm
$74.65
Today
LA1026-B Support Documentation
LA1026-BN-BK7 Plano-Convex Lens, Ø2.0 mm, f = 6 mm, AR Coating: 650 - 1050 nm
$74.65
Today
Back to Top

Ø3.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1036-B 3.0 6.0 +166.7 3.1 1.5 1.0 5.01 Plano-Convex Lens Drawing
LA1039-B 3.0 9.0 +111.1 4.7 1.5 1.2 8.01
  • Suggested Fixed Lens Mount: LMR05(/M) or MLH05(/M) with an LMRA3 Glue-In Adapter for Ø3 mm Optics
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1036-B Support Documentation
LA1036-BN-BK7 Plano-Convex Lens, Ø3.0 mm, f = 6 mm, AR Coating: 650 - 1050 nm
$74.65
Today
LA1039-B Support Documentation
LA1039-BN-BK7 Plano-Convex Lens, Ø3.0 mm, f = 9 mm, AR Coating: 650 - 1050 nm
$74.65
Today
Back to Top

Ø6.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1116-B 6.0 10.0 +100.0 5.2 2.5 1.5 8.3 Plano-Convex Lens Drawing
LA1470-B 6.0 12.0 +83.3 6.2 2.3 1.5 10.5
LA1222-B 6.0 14.9 +66.6 7.7 2.1 1.5 13.6
LA1700-B 6.0 29.9 +33.3 15.5 1.8 1.5 28.7
  • Suggested Fixed Lens Mount: LMR6(/M) or MLH6(/M)
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1116-B Support Documentation
LA1116-BN-BK7 Plano-Convex Lens, Ø6.0 mm, f = 10 mm, AR Coating: 650 - 1050 nm
$35.94
Today
LA1470-B Support Documentation
LA1470-BN-BK7 Plano-Convex Lens, Ø6.0 mm, f = 12 mm, AR Coating: 650 - 1050 nm
$34.45
Today
LA1222-B Support Documentation
LA1222-BN-BK7 Plano-Convex Lens, Ø6.0 mm, f = 15 mm, AR Coating: 650 - 1050 nm
$34.45
Today
LA1700-B Support Documentation
LA1700-BN-BK7 Plano-Convex Lens, Ø6.0 mm, f = 30 mm, AR Coating: 650 - 1050 nm
$33.85
Today
Back to Top

Ø9.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1576-B 9.0 12.0 +83.3 6.2 3.0 1.5 9.7 Plano-Convex Lens Drawing
LA1472-B 9.0 19.9 +50.0 10.3 2.5 1.5 18.3
  • Suggested Fixed Lens Mount: LMR9(/M) or MLH9(/M)
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1576-B Support Documentation
LA1576-BN-BK7 Plano-Convex Lens, Ø9.0 mm, f = 12 mm, AR Coating: 650 - 1050 nm
$37.14
3 weeks
LA1472-B Support Documentation
LA1472-BN-BK7 Plano-Convex Lens, Ø9.0 mm, f = 20 mm, AR Coating: 650 - 1050 nm
$34.45
Today
Back to Top

Ø1/2" (12.7 mm) N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1540-B 1/2" 14.9 +66.7 7.7 5.1 1.8 11.6 Plano-Convex Lens Drawing
LA1074-B 1/2" 19.9 +50.0 10.3 4.0 1.8 17.3
LA1560-B 1/2" 24.9 +40.0 12.9 3.5 1.8 22.6
LA1289-B 1/2" 29.9 +33.3 15.5 3.2 1.8 27.8
LA1304-B 1/2" 39.9 +25.0 20.6 2.8 1.8 38.0
LA1213-B 1/2" 49.8 +20.0 25.8 2.6 1.8 48.1
LA1207-B 1/2" 99.7 +10.0 51.5 2.2 1.8 98.2
  • Suggested Fixed Lens Mount: LMR05(/M) or MLH05(/M)
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1540-B Support Documentation
LA1540-BN-BK7 Plano-Convex Lens, Ø1/2", f = 15 mm, AR Coating: 650 - 1050 nm
$37.14
Today
LA1074-B Support Documentation
LA1074-BN-BK7 Plano-Convex Lens, Ø1/2", f = 20 mm, AR Coating: 650 - 1050 nm
$36.54
Today
LA1560-B Support Documentation
LA1560-BN-BK7 Plano-Convex Lens, Ø1/2", f = 25 mm, AR Coating: 650 - 1050 nm
$34.75
3 weeks
LA1289-B Support Documentation
LA1289-BN-BK7 Plano-Convex Lens, Ø1/2", f = 30 mm, AR Coating: 650 - 1050 nm
$34.45
Today
LA1304-B Support Documentation
LA1304-BN-BK7 Plano-Convex Lens, Ø1/2", f = 40 mm, AR Coating: 650 - 1050 nm
$33.85
3 weeks
LA1213-B Support Documentation
LA1213-BN-BK7 Plano-Convex Lens, Ø1/2", f = 50 mm, AR Coating: 650 - 1050 nm
$33.85
Today
LA1207-B Support Documentation
LA1207-BN-BK7 Plano-Convex Lens, Ø1/2", f = 100 mm, AR Coating: 650 - 1050 nm
$33.85
Today
Back to Top

Ø18.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1859-B 18.0 19.9 +50.0 10.3 7.1 1.8 15.3 Plano-Convex Lens Drawing
LA1270-B 18.0 24.9 +40.0 12.9 5.5 1.8 21.3
LA1085-B 18.0 29.9 +33.3 15.5 4.7 1.8 26.8
LA1119-B 18.0 49.8 +20.0 25.8 3.4 1.8 47.6
  • Suggested Fixed Lens Mount: LMR18(/M
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1859-B Support Documentation
LA1859-BN-BK7 Plano-Convex Lens, Ø18.0 mm, f = 20 mm, AR Coating: 650 - 1050 nm
$38.03
Today
LA1270-B Support Documentation
LA1270-BN-BK7 Plano-Convex Lens, Ø18.0 mm, f = 25 mm, AR Coating: 650 - 1050 nm
$37.14
Today
LA1085-B Support Documentation
LA1085-BN-BK7 Plano-Convex Lens, Ø18.0 mm, f = 30 mm, AR Coating: 650 - 1050 nm
$36.23
Today
LA1119-B Support Documentation
LA1119-BN-BK7 Plano-Convex Lens, Ø18.0 mm, f = 50 mm, AR Coating: 650 - 1050 nm
$36.23
Today
Back to Top

Ø25 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1252-B 25.0 25.4 +39.4 13.1 11.7 2.5 17.7 Plano-Convex Lens Drawing
LA1255-B 25.0 50.1 +20.0 25.8 5.3 2.07 46.6
LA1257-B 25.0 74.9 +13.3 38.6 4.10 2.02 72.2
LA1251-B 25.0 100.0 +10.0 51.5 3.60 2.06 97.6
LA1253-B 25.0 200.0 +5.0 103.0 2.80 2.04 198.1
  • Suggested Fixed Lens Mount: LMR1(/M)
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1252-B Support Documentation
LA1252-BN-BK7 Plano-Convex Lens, Ø25 mm, f = 25 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1255-B Support Documentation
LA1255-BN-BK7 Plano-Convex Lens, Ø25 mm, f = 50 mm, AR Coating: 650 - 1050 nm
$38.60
Today
LA1257-B Support Documentation
LA1257-BN-BK7 Plano-Convex Lens, Ø25 mm, f = 75 mm, AR Coating: 650 - 1050 nm
$37.41
Today
LA1251-B Support Documentation
LA1251-BN-BK7 Plano-Convex Lens, Ø25 mm, f = 100 mm, AR Coating: 650 - 1050 nm
$37.41
Today
LA1253-B Support Documentation
LA1253-BN-BK7 Plano-Convex Lens, Ø25 mm, f = 200 mm, AR Coating: 650 - 1050 nm
$35.94
Today
Back to Top

Ø1" (25.4 mm) N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1951-B 1" 25.3 +39.4 13.1 11.7 1.8 17.6 Plano-Convex Lens Drawing
LA1805-B 1" 29.9 +33.3 15.5 8.6 2.0 24.2
LA1027-B 1" 34.9 +28.6 18.0 7.2 2.0 30.1
LA1422-B 1" 39.9 +25.0 20.6 6.4 2.0 35.7
LA1131-B 1" 49.8 +20.0 25.8 5.3 2.0 46.3
LA1134-B 1" 59.8 +16.7 30.9 4.7 2.0 56.7
LA1608-B 1" 74.8 +13.3 38.6 4.1 2.0 72.0
LA1509-B 1" 99.7 +10.0 51.5 3.6 2.0 97.3
LA1986-B 1" 124.6 +8.0 64.4 3.3 2.0 122.4
LA1433-B 1" 149.5 +6.7 77.3 3.1 2.0 147.5
LA1229-B 1" 174.4 +5.7 90.1 2.9 2.0 172.5
LA1708-B 1" 199.3 +5.0 103.0 2.8 2.0 197.5
LA1461-B 1" 249.2 +4.0 128.8 2.6 2.0 247.4
LA1484-B 1" 299.0 +3.3 154.5 2.5 2.0 297.3
LA1172-B 1" 398.7 +2.5 206.0 2.4 2.0 397.1
LA1908-B 1" 498.3 +2.0 257.5 2.3 2.0 496.8
LA1978-B 1" 747.5 +1.3 386.3 2.2 2.0 746.1
LA1464-B 1" 996.7 +1.0 515.1 2.2 2.0 995.3
LA1254-Bc 1" 1500.0 +0.7 775.2 2.1 2.0 1498.6
LA1258-Bc 1" 2000.0 +0.5 1033.6 2.1 2.0 1998.6
LA1259-Bc 1" 2500.0 +0.4 1292.0 2.1 2.0 2498.6
  • Suggested Fixed Lens Mount: LMR1(/M
  • Reciprocal of the Focal Length in Meters
  • The engraved arrow on lens edge points toward the curved surface.
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1951-B Support Documentation
LA1951-BN-BK7 Plano-Convex Lens, Ø1", f = 25 mm, AR Coating: 650 - 1050 nm
$39.90
Today
LA1805-B Support Documentation
LA1805-BN-BK7 Plano-Convex Lens, Ø1", f = 30 mm, AR Coating: 650 - 1050 nm
$39.30
Today
LA1027-B Support Documentation
LA1027-BN-BK7 Plano-Convex Lens, Ø1", f = 35 mm, AR Coating: 650 - 1050 nm
$38.43
Today
LA1422-B Support Documentation
LA1422-BN-BK7 Plano-Convex Lens, Ø1", f = 40 mm, AR Coating: 650 - 1050 nm
$38.15
Today
LA1131-B Support Documentation
LA1131-BN-BK7 Plano-Convex Lens, Ø1", f = 50 mm, AR Coating: 650 - 1050 nm
$37.28
Today
LA1134-B Support Documentation
LA1134-BN-BK7 Plano-Convex Lens, Ø1", f = 60 mm, AR Coating: 650 - 1050 nm
$36.98
Today
LA1608-B Support Documentation
LA1608-BN-BK7 Plano-Convex Lens, Ø1", f = 75 mm, AR Coating: 650 - 1050 nm
$36.98
Today
LA1509-B Support Documentation
LA1509-BN-BK7 Plano-Convex Lens, Ø1", f = 100 mm, AR Coating: 650 - 1050 nm
$36.11
Today
LA1986-B Support Documentation
LA1986-BN-BK7 Plano-Convex Lens, Ø1", f = 125 mm, AR Coating: 650 - 1050 nm
$36.11
Today
LA1433-B Support Documentation
LA1433-BN-BK7 Plano-Convex Lens, Ø1", f = 150 mm, AR Coating: 650 - 1050 nm
$35.24
Today
LA1229-B Support Documentation
LA1229-BN-BK7 Plano-Convex Lens, Ø1", f = 175 mm, AR Coating: 650 - 1050 nm
$34.94
Today
LA1708-B Support Documentation
LA1708-BN-BK7 Plano-Convex Lens, Ø1", f = 200 mm, AR Coating: 650 - 1050 nm
$34.94
Today
LA1461-B Support Documentation
LA1461-BN-BK7 Plano-Convex Lens, Ø1", f = 250 mm, AR Coating: 650 - 1050 nm
$34.66
Today
LA1484-B Support Documentation
LA1484-BN-BK7 Plano-Convex Lens, Ø1", f = 300 mm, AR Coating: 650 - 1050 nm
$34.66
Today
LA1172-B Support Documentation
LA1172-BN-BK7 Plano-Convex Lens, Ø1", f = 400 mm, AR Coating: 650 - 1050 nm
$34.66
Today
LA1908-B Support Documentation
LA1908-BN-BK7 Plano-Convex Lens, Ø1", f = 500 mm, AR Coating: 650 - 1050 nm
$34.66
Today
LA1978-B Support Documentation
LA1978-BN-BK7 Plano-Convex Lens, Ø1", f = 750 mm, AR Coating: 650 - 1050 nm
$34.66
Today
LA1464-B Support Documentation
LA1464-BN-BK7 Plano-Convex Lens, Ø1", f = 1000 mm, AR Coating: 650 - 1050 nm
$34.36
Today
LA1254-B Support Documentation
LA1254-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1", f = 1500 mm, AR Coating: 650 - 1050 nm
$32.98
Today
LA1258-B Support Documentation
LA1258-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1", f = 2000 mm, AR Coating: 650 - 1050 nm
$32.98
Today
LA1259-B Support Documentation
LA1259-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1", f = 2500 mm, AR Coating: 650 - 1050 nm
$32.98
Today
Back to Top

Ø30.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1274-B 30.0 39.9 +25.0 20.6 9.0 2.5 34.0 Plano-Convex Lens Drawing
LA1102-B 30.0 49.8 +20.0 25.8 7.3 2.5 45.0
LA1765-B 30.0 74.8 +13.3 38.6 5.5 2.5 71.1
LA1031-B 30.0 99.7 +10.0 51.5 4.7 2.5 96.5
LA1907-B 30.0 149.5 +6.7 77.3 3.1 1.6 147.5
LA1541-B 30.0 199.3 +5.0 103.0 2.8 1.7 197.5
LA1832-B 30.0 249.2 +4.0 128.8 2.6 1.7 247.4
LA1419-B 30.0 299.0 +3.3 154.5 2.5 1.8 297.3
LA1237-B 30.0 498.3 +2.0 257.5 2.3 1.8 496.8
  • Suggested Fixed Lens Mount: LMR30(/M
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1274-B Support Documentation
LA1274-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 40 mm, AR Coating: 650 - 1050 nm
$45.74
Today
LA1102-B Support Documentation
LA1102-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 50 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1765-B Support Documentation
LA1765-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 75 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1031-B Support Documentation
LA1031-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 100 mm, AR Coating: 650 - 1050 nm
$40.98
Today
LA1907-B Support Documentation
LA1907-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 150 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1541-B Support Documentation
LA1541-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 200 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1832-B Support Documentation
LA1832-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 250 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1419-B Support Documentation
LA1419-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 300 mm, AR Coating: 650 - 1050 nm
$41.29
Today
LA1237-B Support Documentation
LA1237-BN-BK7 Plano-Convex Lens, Ø30.0 mm, f = 500 mm, AR Coating: 650 - 1050 nm
$41.29
Today
Back to Top

Ø1.5" (38.1 mm) N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1385-B 1.5" 50.0 +20.0 25.8 10.9 2.5 42.8 Plano-Convex Lens Drawing
LA1386-B 1.5" 75.0 +13.3 38.8 7.5 2.5 70.1
LA1387-B 1.5" 100.0 +10.0 51.7 6.1 2.5 96.0
LA1388-B 1.5" 150.0 +6.7 77.5 4.9 2.5 146.8
LA1389-B 1.5" 200.0 +5.0 103.4 4.3 2.5 197.2
  • Suggested Fixed Lens Mount: LMR1.5(/M)
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1385-B Support Documentation
LA1385-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1.5", f = 50 mm, AR Coating: 650 - 1050 nm
$47.24
Today
LA1386-B Support Documentation
LA1386-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1.5", f = 75 mm, AR Coating: 650 - 1050 nm
$47.24
Today
LA1387-B Support Documentation
LA1387-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1.5", f = 100 mm, AR Coating: 650 - 1050 nm
$46.90
Today
LA1388-B Support Documentation
LA1388-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1.5", f = 150 mm, AR Coating: 650 - 1050 nm
$47.24
Today
LA1389-B Support Documentation
LA1389-BCustomer Inspired! N-BK7 Plano-Convex Lens, Ø1.5", f = 200 mm, AR Coating: 650 - 1050 nm
$47.24
Today
Back to Top

Ø2" (50.8 mm) N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1401-B 2" 59.8 +16.7 30.9 16.3 3.0 49.1 Plano-Convex Lens Drawing
LA1145-B 2" 74.8 +13.3 38.6 12.5 3.0 66.5
LA1050-B 2" 99.7 +10.0 51.5 9.7 3.0 93.3
LA1384-B 2" 124.6 +8.0 64.4 8.2 3.0 119.2
LA1417-B 2" 149.5 +6.7 77.3 7.3 3.0 144.7
LA1399-B 2" 174.4 +5.7 90.1 6.7 3.0 170.0
LA1979-B 2" 199.3 +5.0 103.0 6.2 3.0 195.3
LA1301-B 2" 249.2 +4.0 128.8 5.5 3.0 245.5
LA1256-B 2" 299.0 +3.3 154.5 5.1 3.0 295.6
LA1725-B 2" 398.7 +2.5 206.0 4.6 3.0 395.7
LA1380-B 2" 498.3 +2.0 257.3 4.3 3.0 495.5
LA1727-B 2" 747.5 +1.3 386.3 3.8 3.0 745.0
LA1779-B 2" 996.7 +1.0 515.1 3.6 3.0 994.3
  • Suggested Fixed Lens Mount: LMR2(/M
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1401-B Support Documentation
LA1401-BN-BK7 Plano-Convex Lens, Ø2", f = 60 mm, AR Coating: 650 - 1050 nm
$54.04
Today
LA1145-B Support Documentation
LA1145-BN-BK7 Plano-Convex Lens, Ø2", f = 75 mm, AR Coating: 650 - 1050 nm
$50.80
Today
LA1050-B Support Documentation
LA1050-BN-BK7 Plano-Convex Lens, Ø2", f = 100 mm, AR Coating: 650 - 1050 nm
$46.33
Today
LA1384-B Support Documentation
LA1384-BN-BK7 Plano-Convex Lens, Ø2", f = 125 mm, AR Coating: 650 - 1050 nm
$46.33
Today
LA1417-B Support Documentation
LA1417-BN-BK7 Plano-Convex Lens, Ø2", f = 150 mm, AR Coating: 650 - 1050 nm
$45.74
Today
LA1399-B Support Documentation
LA1399-BN-BK7 Plano-Convex Lens, Ø2", f = 175 mm, AR Coating: 650 - 1050 nm
$65.33
3 weeks
LA1979-B Support Documentation
LA1979-BN-BK7 Plano-Convex Lens, Ø2", f = 200 mm, AR Coating: 650 - 1050 nm
$45.74
Today
LA1301-B Support Documentation
LA1301-BN-BK7 Plano-Convex Lens, Ø2", f = 250 mm, AR Coating: 650 - 1050 nm
$65.33
Today
LA1256-B Support Documentation
LA1256-BN-BK7 Plano-Convex Lens, Ø2", f = 300 mm, AR Coating: 650 - 1050 nm
$47.82
Today
LA1725-B Support Documentation
LA1725-BN-BK7 Plano-Convex Lens, Ø2", f = 400 mm, AR Coating: 650 - 1050 nm
$48.12
Today
LA1380-B Support Documentation
LA1380-BN-BK7 Plano-Convex Lens, Ø2", f = 500 mm, AR Coating: 650 - 1050 nm
$48.12
Today
LA1727-B Support Documentation
LA1727-BN-BK7 Plano-Convex Lens, Ø2", f = 750 mm, AR Coating: 650 - 1050 nm
$62.67
Today
LA1779-B Support Documentation
LA1779-BN-BK7 Plano-Convex Lens, Ø2", f = 1000 mm, AR Coating: 650 - 1050 nm
$62.67
Today
Back to Top

Ø75.0 mm N-BK7 Plano-Convex Lenses (AR Coating: 650 - 1050 nm)

Item #a Diameter
(mm)
Focal Length
(mm)
Diopterb Radius of Curvature
(mm)
Center Thickness
(mm)
Edge Thickness
(mm)
Back Focal Length
(mm)
Reference
Drawing
LA1740-B 75.0 84.7 +11.8 43.8 24.2 3.0 68.8 Plano-Convex Lens Drawing
LA1238-B 75.0 99.7 +10.0 51.5 19.2 3.0 87.0
LA1002-B 75.0 149.5 +6.7 77.3 12.7 3.0 141.1
LA1353-B 75.0 199.3 +5.0 103.0 10.1 3.0 192.7
  • Suggested Fixed Lens Mount: LMR75(/M
  • Reciprocal of the Focal Length in Meters
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
LA1740-B Support Documentation
LA1740-BN-BK7 Plano-Convex Lens, Ø75.0 mm, f = 85 mm, AR Coating: 650 - 1050 nm
$112.57
Today
LA1238-B Support Documentation
LA1238-BN-BK7 Plano-Convex Lens, Ø75.0 mm, f = 100 mm, AR Coating: 650 - 1050 nm
$112.57
Today
LA1002-B Support Documentation
LA1002-BN-BK7 Plano-Convex Lens, Ø75.0 mm, f = 150 mm, AR Coating: 650 - 1050 nm
$112.57
Today
LA1353-B Support Documentation
LA1353-BN-BK7 Plano-Convex Lens, Ø75.0 mm, f = 200 mm, AR Coating: 650 - 1050 nm
$112.57
Today