滤光片/衰减器安装座,用于多模光纤


  • Reflective, Achromatic Design for 250 nm - 450 nm or 450 nm - 20 µm
  • Mount Filters, Cuvettes, or Variable Attenuator in the Optical Path
  • Ideal for Ø200 µm to Ø1000 µm Core Multimode Fibers with ≤0.39 NA
  • Models with FC/PC or SMA Connectors

CFH2-B

Blank Insert

FOFMS

SMA Connectors,
Shown with One Filter
Holder Removed

Two SM1-Threaded (1.035"-40) Filter Holders are Included with Each Mount

Application Idea

Each filter holder can be replaced with a macro or micro cuvette, making the in-line fiber filter mounts ideal for absorption spectroscopy. See the Application tab for details.

CFH2-V

Variable Attenuator Insert

Related Items


Please Wait
In-Line Filter Mount
Click for Details

通过同轴式滤光片安装座的光路示意图
In-Line Filter Mount
Click to Enlarge

能够轻松地拆卸和替换Ø1英寸滤光片

In-Line Filter Mount
Click to Enlarge

利用BA2R磁性底座将FOFMF安装到光学平台

特性

  • 使用离轴抛物面(OAP)反射镜的自由空间、光纤对光纤的耦合系统
    • 紫外增强型铝膜(250 nm - 450 nm),用于紫外光源
    • 有保护层的银膜(450 nm - 20 µm),用于宽带光源
  • FC/PC或SMA接头
    • 产品型号前缀是FOFMF的版本兼容2.2 mm宽键和2.0 mm窄键接头
    • 产品型号前缀是FOFMS的版本用于SMA905接头
  • 每个安装座附带两个CFH2-F Ø1英寸滤光片架
  • 兼容常量和微量的比色皿(不包含在安装座中,请见规格标签了解详情)
  • 底部有1/4"-20(M6)螺孔,用于安装到接杆或任意安装底座
  • 下方单独提供的配件
    • 更换用的滤光片架
    • 空白插条
    • 可调衰减插条
    • 遮光罩

Thorlabs的同轴式光纤滤光片安装座非常适合需要先滤光或降低光强的光纤应用。如右图所示,每个安装座都由两个可拆卸的CFH2-F滤光片架构成,形成一个包含自由空间和光纤对光纤的固定耦合系统。该系统使用两面离轴抛物面(OAP)反射镜来准直从输入光纤射出的光,并将其耦合到输出光纤中。使用这些反射镜能够在整个反射带上提供高反射率、高NA和消色差性能。更多有关OAP反射镜的信息,请看规格标签。全反射设计消除了透射光学元件引入的相位延迟和吸收损耗。

每个滤光片架都可由一个12.5 mm x 12.5 mm的合成石英玻璃比色皿(不包含)替换,因此非常适合吸收或透射光谱的测量(请看应用标签了解详情)。如果使用两个滤光片架,或者使用FOFM-CV遮光罩,可以搭建闭光系统。

如需定制接头、反射镜镀膜或滤光片架,请联系技术支持techsupport-cn@thorlabs.com

光纤兼容性
Thorlabs的同轴式滤光片安装座可以与多模光纤一起使用。一般而言,这些安装座不能用于单模光纤,因为在没有精确对准的情况下,将光耦合到纤芯很细的单模光纤时会产生很大的损耗。但是,如果输出端连接的是多模光纤,则可以将单模光纤用作安装座的输入光纤。

滤光片支架、空白笼板和可调衰减插条
每个SM1(1.035"-40)螺纹的滤光片支架可以用来安装最厚0.31英寸(8.0 mm)的各种Ø1英寸滤光片。滤光片支架可以拆卸,利用装载弹簧的精密燕尾设计实现重复定位。每个滤光片支架顶部刻有两个文本框,用于标识所安装的光学元件。此外,可使用SM1A6T螺纹转接件安装Ø1/2英寸滤光片。额外的滤光片支架可在下方单独购买。

如果内附的滤光片支架不适合您的应用,下方还单独出售CFH2-B无孔笼板。该笼板与附带的CFH2-F具有相同的安装方法,可以根据您的特殊要求进行加工。此外,它还可当作手动快门使用。CFH2-V可调衰减器插条可以代替滤光片支架,挡住部分或全部光的通过。它还具有衰减分辨率为±0.01 dB的调节器(用于纤芯Ø200 - Ø1000 µm、数值孔径0.22 - 0.50的光纤时),能通过快速释放机制迅速挡住孔径。

遮光罩
Thorlabs提供用于滤光片安装座的遮光罩,适合对光特别敏感的应用。该遮光罩兼容最高50 mm(1.96英寸)的比色皿(包括塞子)。请注意,FOFM-CV不兼容CFH2-V衰减插条。

安装选项
底部的1/4"-20(M6)螺孔可用来将同轴式滤光片安装座安装到Ø1/2英寸接杆接杆架底座上,比如BA2R磁性底座(如上图所示)或UBP2通用底座。如果需要更多空间将其他光学元件放置在自由空间光路中,我们提供可调光程的光纤-光纤耦合器,通过燕尾导轨提供最大500 mm的准直器间距。

我们也提供比色皿支架,用于自由空间荧光测量等应用。

Item #FOFMF(/M)-UVFOFMS(/M)-UVFOFMF(/M)FOFMS(/M)
Compatible ConnectorsFC/PCaSMA905FC/PCaSMA905
Recommended Input NAb≤0.39 NA
Insertion Lossc
(No Filters or Cuvettes)
< 3.5 dB @ 250 - 350 nmd
< 2.0 dB @ 350 - 450 nmd
≤2 dB @ 450 nm - 20 µme
Filter HoldersTwo Included (CFH2-F)
Compatible Filter DimensionsØ1" (25.4 mm),
0.31" (8.0 mm) Thick
Compatible Cuvette Dimensionsf12.5 mm x 12.5 mm
(0.49" x 0.49")
Mount Dimensions (Excluding Filter Holder)2.00" x 3.31" x 1.60"
(50.8 mm x 84.0 mm x 40.6 mm)
Mount Dimensions (Including Filter Holder)2.00" x 3.31" x 2.28"
(50.8 mm x 84.0 mm x 57.9 mm)
Tap1/4"-20 (M6)
Off-Axis Parabolic Mirror Specificationsg
Item #MPD00M9-F01MPD00M9-P01
CoatingUV-Enhanced AluminumProtected Silver
Reflectance (Average)
Click for Plot
>90%, 250 - 450 nm>97%, 450 nm - 2 µm
>96%, 2 - 20 µm
Off-Axis Angle90°
Reflected Focal Length15.0 mm (0.59")
Surface Roughness < 100 Å (RMS)
Reflected Wavefront Error λ/4 at 633 nm
Surface Quality40-20 Scratch-Dig
  • 兼容宽键和窄键FC/PC接头。
  • 可以使用最大0.5 NA的光纤,但是这会增加插入损耗。
  • 插入单个比色皿时,菲涅耳反射会使插入损耗增加大约0.64 dB。请看插入损耗标签了解更多信息。这些值针对多模光纤有效。
  • 适合250 nm - 450 nm波长范围内纤芯在Ø200 µm - Ø600 µm、数值孔径≤0.39的抗负感光纤
  • 适合450 nm - 20 µm波长范围内纤芯在Ø200 µm - Ø1000 µm、数值孔径≤0.39的光纤。
  • 比色皿不包含在安装座中,但可以点击这里购买。
  • 欲了解更多信息,请查看有保护层银膜紫外增强型铝膜OAP的完整网页描述。

准直后的光束直径

In-Line Filter Mount
Click to Enlarge

通过同轴式光纤滤光片安装座的光路示意图

利用光纤的数值孔径(NA)和OAP的反射焦距计算光束直径。以小角度近似计算光束直径时,使用如下公式:

光束直径 = 2 x NA (光纤) x 反射焦距

下表列出了输出光束直径与反射镜焦距和光纤数值孔径的函数变化关系。OAP的通光孔径应该大于输出光束直径的计算值

Fiber NABeam DiameterOAP Clear Aperture
0.103 mm>Ø11.43 mm
0.206 mm
0.3911.7 mma
0.5012.7 mma
  • 受到OAP反射镜的通光孔径限制

插入损耗与波长的关系

下方曲线图比较了不同光纤类型的插入损耗与波长的关系。阴影区域表示用于同轴式光纤滤光片安装座的特定波长范围和插入损耗。特定波长时的插入损耗也取决于所用光纤的性能,且在无滤光片和比色皿的情况下测得。

Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的曲线图为中红外多模光纤跳线与模式剥离的光纤耦合时,450 nm - 250 µm波长范围的滤光片安装座的典型插入损耗与波长的关系。此图还可用来与低羟基石英光纤跳线和理论无损光纤进行对比。测量数据使用Thorlabs的SLS202L宽带光源aOSA201COSA207C光谱仪获得。
  • a.此型号不再提供购买。具有相似性能的稳定型光源在这里提供。有关具体应用的咨询,请联系技术支持techsupport-cn@thorlabs.com
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的曲线图为与0.22 NA抗负感光纤跳线一起使用时,250 nm - 450 nm波长范围的滤光片安装座的典型插入损耗与波长的关系。测量数据使用宽带光源和CCS200光谱仪获得。由于测量数据使用了光谱仪,所测的插入损耗与模式剥离的光纤耦合的插入损耗类似。
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的曲线图比较了450 nm - 250 µm波长范围的FOFMS和250 nm - 450 nm波长范围的FOFMS-UV的典型插入损耗与波长的关系。注意,对于带低羟基石英光纤的FOFMS,接近紫外波长时插入损耗显著增加。相形之下,带抗负感光纤的FOFMS-UV在低至250 nm时插入损耗仍然小于3.5 dB。
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的曲线图为与0.22 NA的不同石英光纤跳线一起使用时,滤光片安装座的典型插入损耗与波长的关系。注意,即使是纤芯50 µm的光纤和光纤束,插入损耗仍在3 dB左右。测量数据使用Thorlabs的SLS201L宽带光源CCS200光谱仪获得。由于测量数据使用了光谱仪,所测的插入损耗与模式剥离的光纤耦合的插入损耗类似。


模式剥离和过满耦合条件下的插入损耗

下图比较了在不同耦合条件下,配合滤光片安装座使用的光纤的性能。模式剥离的(70/70)光纤耦合剥除了在滤光片中损耗的包层模式,而过满(>100%)光纤耦合包含所有的传播模式。由于使用功率计来测量输入功率与输出功率时无法区分这些模式类型,因此模式剥离的光纤耦合条件更适合测量滤光片安装座实际的插入损耗。

Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的数据体现了输入光纤过满(上面有定义)时的负面影响。在此曲线图中,拆下了左边模式剥离范例中使用的针孔,LED的输出直接进入光纤。然后光束通过光纤滤光片支架耦合到S120C功率计中进行测量。
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的数据使用了模式剥离的光纤耦合条件(上面有定义)测量所得。为了满足这个条件,需将一个直径为光纤纤芯70%的针孔放置在旧款M470F3光纤耦合LED的输出光之后。然后,光束通过滤光片安装座并耦合到S120C功率计中进行测量。图中所示的测量结果与使用单模激光光源或芯轴缠绕方法的结果相似。
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的数据体现了输入光纤过满(上面有定义)时的负面影响。在此曲线图中,拆下了左边模式剥离范例中使用的针孔,LED的输出直接进入光纤。然后光束通过光纤滤光片支架耦合到S120VC功率计中进行测量。
Protected Silver at 45 Degree Incident Angle
Click to Enlarge

Excel Spreadsheet with Raw Data
上面的数据使用了模式剥离的光纤耦合条件(上面有定义)测量所得。为了满足这个条件,需将一个直径为光纤纤芯70%的针孔放置在M385F1光纤耦合LED的输出光之后。然后,光束通过滤光片安装座并耦合到S120VC功率计中进行测量。图中所示的测量结果与使用单模激光光源或芯轴缠绕方法的结果相似。
Methanol Absorption Spectrum
Click to Enlarge

甲醇的吸收光谱

吸收光谱学

利用吸收光谱学技术测量样品在特定频率或波长对光的吸收量,可以表征材料光学属性。宽带光源通过样品时,样品将吸收特定频率或波长的一部分入射光。总透射率曲线图中的这些下降区域表示材料独特的吸收光谱。这种技术一般用于材料分析中,可以收集信息了解未知物质的化学成分或溶液中的分子浓度。

右图为甲醇的吸收光谱,测量装置中包含Thorlabs的FOFMS滤光片安装座、一个SLS202L宽带光源a、两根0.20 NA、芯径为Ø200 µm的ZrF4中红外多模光纤跳线和一个CV10Q3500 3500 µL石英比色皿。选择石英比色皿是因为它从紫外到中红外光谱范围内拥有高透过率。此装置的一个类似范例可在本页顶部的图片中看到。

光进入FOFMF滤光片系统时,首先通过第一个带保护层的镀银OAP反射镜准直成直径约为6 mm的光束(详情请看规格标签)。准直光束然后通过两个可以安装Ø1英寸滤光片或比色皿的槽。在这个测量中,我们只安装一个装有甲醇样品的比色皿。光束通过比色皿后,被第二个带保护层的镀银OAP反射镜耦合到输出光纤中,并使用傅立叶变换红外光谱仪(FTIR)进行测量。

a. 此型号不再提供购买。具有相似性能的稳定型光源在这里提供。有关具体应用的咨询,请联系技术支持techsupport-cn@thorlabs.com

离轴抛物面反射镜

请向下滑动了解离轴抛物面(OAP)反射镜的独特性能以及如何利用它们:

  • 为什么使用抛物面反射镜而不是球面反射镜?
  • 离轴抛物面反射镜的优点
  • 基于OAP反射镜的反射式准直器的方向性

点击这里以获取有关实验经验和设备的更多信息。

 

为什么使用抛物面反射镜而不是球面反射镜?

Spherical Mirror Ray Trace with Focus Indicated
Click to Enlarge

图2:球面反射镜无法反射准直光束中的所有光线使其通过单一点。黑点表示聚焦体积中的交点选择。
Parabolic Mirror Ray Trace with Focus Indicated
Click to Enlarge

图1:抛物面反射镜为准直光束中的所有光线提供单一焦点。

准直点光源发出的光或聚焦准直光束时,抛物面反射镜的性能要优于球面反射镜。

聚焦准直光
抛物面反射镜(图1)将入射的准直光束中的所有光线聚焦到衍射极限点。相反,凹球面反射镜(图2)将入射的准直光聚集到大于衍射极限光斑的体积内。可以通过减小入射准直光束的直径来减小球面反射镜的聚焦体积大小。

准直来自点光源的光
点光源向各个方向发光。这样高度发散的光源放置在抛物面反射镜的焦点处时,输出光束将高度准直。如果是理想点光源,则所有反射光线彼此完全平行。

当点源放置在球面反射镜的焦距内时,输出光束的准直度不如抛物面反射镜提供的光束准直。来自点光源的不同光线经过球面反射镜反射后并不是完全平行,但是当两个反射光线从球面反射镜表面上更近距离的点反射时,它们将更接近平行。因此,可以通过减小反射面的面积来提高准直光束的质量。这等效于限制聚焦体积中的光源发射光的角度范围。

选择抛物面反射镜和球面反射镜
抛物面反射镜并非总是更好的选择。光束直径、成本约束、空间限制和应用的性能要求都会影响选择。光束直径是一个因素,因为当光束直径较小时,这两个反射镜的性能更为相似。抛物面反射镜更昂贵,因为其反射轮廓更难制造。抛物面反射镜通常也较大。提高的性能可能比成本和物理尺寸上的差异重要,也可能没那么重要。

Date of Last Edit: Dec. 4, 2019

 

离轴抛物面反射镜的优点

Off-Axis Parabolic Mirror Has Accessible Focal Point
Click to Enlarge

图4:离轴抛物面反射镜可以看作是较大抛物面的一段截面。两者具有相同的焦点,但是在使用OAP反射镜时更容易利用焦点。
On-Axis Parabolic Mirror Has Obstructed Focal Point
Click to Enlarge

图3:轴上抛物面反射镜的焦点靠近反射表面,且通常被反射表面包围,这使光束焦点很难被利用。

凹抛物面反射镜的主要优点之一是其单一焦点。所有平行于反射镜轴传播的光线都会通过该点反射。这可用于多种用途,包括需要将激光聚焦到衍射极限点的成像和制造应用。

使用传统的抛物面反射镜会产生一些负面影响,它们绕焦点对称(图3)。一是反射镜的侧面通常会阻碍对焦点的利用。另一个是当使用反射镜准直发散的光源时,光源的外壳会阻挡一部分准直光束。尤其是相对于反射镜光轴以小角度发射的光通常会被阻挡。

离轴抛物面(OAP)反射镜(图4)是解决此问题的一种方法。该反射镜的反射表面呈抛物线形,但在焦点周围不对称。OAP的反射面对应于母抛物面远离焦点的截面。所选截面取决于所需角度和/或焦点与反射镜中心之间的距离。

Date of Last Edit: Dec. 4, 2019

 

基于OAP反射镜的反射式准直器的方向性

Cut-away view of OAP-based fiber collimator
Click to Enlarge

图6:准直器的反射元件为离轴抛物面反射镜。反射镜基底以红色高亮显示。反射表面的形状为抛物线曲线偏离顶点的截面。母抛物面和OAP反射镜的焦点重合。
OAP-based fiber collimator
Click to Enlarge

图5:Thorlabs提供反射式准直器,包括一个端口用于光纤接口,另一个端口用于自由空间、平行于光轴传播的准直光。

Thorlabs的反射式准直器上的两个端口不可互换。 一个端口具有光纤接头,需要点光源的高度发散光。另一个端口专用于准直的自由空间光(图5)。

自由空间端口
输入到该端口的光应准直并定向平行于光轴。不可输入来自光纤端面、激光二极管或其他光源的光。这种光不会在光纤接头端口处准直,也不会耦合到连接光纤端口的光纤中。

光纤接头端口
此端口将光纤的端面与反射镜的焦点对齐。由于光纤的端面接近放置在焦点处的点光源,因此从自由空间端口输出准直光束。光纤端面与焦点对齐的原因也是所有输入至自由空间端口的光应准直并定向平行于光轴的原因。

方向性来源
准直器的方向性是使用非旋转对称、离轴抛物面(OAP)反射镜作为反射元件的结果(图6)。剖视图说明了光纤端面位于母抛物面的焦点,这也是OAP反射镜的焦点。

Date of Last Edit: Dec. 4, 2019


Posted Comments:
Gerhard Sedlmeier  (posted 2023-02-08 09:27:33.6)
Hi Thorlabs team, are there any reflectance data below 250nm available? Thank you for a short response. BR Gerhard Seldmeier
jgreschler  (posted 2023-02-08 02:17:12.0)
Thank you for reaching out to Thorlabs. Extended data and additional specs can be requested by contacting techsupport@thorlabs.com. I have reached out to you directly to discuss this application.
Michael Wagner  (posted 2022-09-16 12:49:38.383)
Hi! It would be nice if there was a Filter Holder with which a filter can be angled against the optical axis. It might take up both slots, but that would be an OK tradeoff. Also, it would be nice if there was a holder for filter holder inserts, to protect them against dust, while not in use. Sincerely, Michael Wagner
Mateo Gutierrez  (posted 2022-07-29 16:45:40.787)
I was interested in this product ( https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=10066 ). However, is there any way to mount variable ND filter wheels to a coupled fiber ? Looking forward to seeing your response, Mateo
jgreschler  (posted 2022-08-04 03:39:53.0)
Thank you for reaching out to Thorlabs. While this unit is incompatible with our filter wheels there may be alternatives that will work in a similar way that are compatible. I have reached out to you directly to discuss this application further.
Pattabhi Dyta  (posted 2022-07-23 15:14:43.31)
Please suggest SMA-SMA attenuator for this category.
jgreschler  (posted 2022-07-26 09:40:29.0)
Thank you for reaching out to Thorlabs. Depending on the wavelength range of your application either the FOFMS or the FOFMS-UV are the recommended filter mounts, coupled with the CFH2-V variable attenuator insert would work for this purpose. I have reached out to you directly to discuss your specific application.
Guillaume Gilson  (posted 2022-03-03 05:19:46.507)
Hi, What is the maximum optical power rating for this mount. Would it be okay for use with 10W MM beam? Thanks a lot!
cdolbashian  (posted 2022-03-04 04:33:18.0)
Thank you for reaching out to us Guillaume. The mirror used in the FOFMF has a damage threshold of 2kW/cm for 10.6um and 1070nm wavelengths. Using 2kW/cm as the upper limit of density, and your power of 10W, you would need a spot size of 50 um to damage the mirror. In this case, since your beam will be diverging from your fiber before it reaches the mirror, it is unlikely that your spot size will be even close to that small. Likely there will be no issue here. I have emailed you directly to discuss your specific light source.
Holger Tuitje  (posted 2021-03-05 12:48:57.763)
Hello, Please can you consider to design it without the two sidewalls (the wall that currently has the model number and the opposite wall). Basically, when the internal components are removed it is a more open and accessible design. I have a picture that I could send. Thanks, Holger Tuitje
YLohia  (posted 2021-03-05 03:02:56.0)
Hello Holger, custom options of the FOFMS-UV can be requested by clicking on the "Request Quote" button above or by emailing your local Thorlabs team (in your case, techsupport@thorlabs.com). We will discuss the possibility of offering this directly.
Alex Barker  (posted 2021-01-14 06:59:43.75)
I love the design, but some part of the thread has stripped itself, rendering the item fairly useless. It hasn't had particularly high usage either.
YLohia  (posted 2021-01-22 02:16:00.0)
Hello, thank you for your feedback. We're sorry to hear about the issues you're having with this item. Since we haven't received any complaints or requests for RMA for this item since its release, I was hoping that you could answer some questions about the use of this item so we can take appropriate corrective action. What was the Thorlabs Sales Order Number under which this was purchased and how long have you had this unit? Did you unthread or remove the adjuster from the main mount? If the slit isn't moving, perhaps the adjuster is not truly stripped. The adjuster screw can spin loosely if its top bushing pops out of the top plate. I had reached out to you directly at the time of your original posting.
Georg Ramer  (posted 2021-01-11 14:40:14.127)
Is it possible to use the FOFMF/M with FC/APC fibers? How does this affect the performance?
YLohia  (posted 2021-01-12 02:42:20.0)
Hello, we do not recommend using the FOFMF/M with FC/APC connectors since the bulkheads are not aligned for the angled ferrule of APC connectors. Using APC connectors will significantly increase insertion loss (the exact value depends on fiber core size and NA). Custom bulkhead options can be requested by emailing your local Thorlabs Tech Support team (in your case, europe@thorlabs.com).
user  (posted 2017-06-06 01:15:07.27)
A motorized version of this would also be very useful.
tfrisch  (posted 2017-06-22 09:50:42.0)
Hello, thank you for your feedback. I have posted it in our internal engineering forum.
cbrideau  (posted 2017-05-03 12:55:52.423)
A version of this that acts as a simple latchable shutter would also be useful for hands-free blocking of the beam.
nbayconich  (posted 2017-05-17 02:37:06.0)
Thank you for contacting Thorlabs. A techsupport representative will reach out to you directly.
Back to Top

同轴式滤光片安装座,用于多模光纤

Key Specificationsa
Item NumberFOFMF(/M)-UVFOFMS(/M)-UVFOFMF(/M)FOFMS(/M)
CoatingUV-Enhanced AluminumProtected Silver
Coating Reflectance>90%, 250 - 450 nm>97%, 450 nm - 2 µm
>96%, 2 - 20 µm
Insertion Lossb≤3.5 dB (250 nm - 350 nm)c
≤2 dB (350 nm - 450 nm)c
≤2 dB (450 - 20 µm)d
Compatible ConnectorsFC/PCeSMA905FC/PCeSMA905
Tap1/4"-20 (M6)
  • 其他规格,请看规格标签。
  • 更多信息,请看插入损耗标签。
  • 指定用于纤芯Ø200 µm - Ø600 µm、数值孔径≤0.39的抗负感光纤
  • 指定用于纤芯Ø200 µm - Ø1000 µm、数值孔径≤0.39的光纤。
  • 兼容窄键和宽键接头。
  • 安装座适用于250 nm - 450 nm或450 nm - 20 µm
  • 非常适合纤芯Ø200 µm - Ø1000 µm、数值孔径≤0.39的多模光纤
  • 兼容FC/PC或SMA905接头
  • OAP反射镜,镀紫外增强型铝膜或有保护层银膜

这些同轴式多模光纤滤光片安装座包含OAP反射镜,用于准直并耦合光束。镀紫外增强型铝膜的反射镜用于250 nm - 450 nm,非常适合我们的抗负感光纤跳线。镀有保护层银膜的反射镜在450 nm - 20 µm的范围上提供宽带性能。这些安装座兼容我们的多模光纤跳线

+1 数量 文档 产品型号 - 英制 单价 现货 / 发货日
FOFMF-UV Support Documentation
FOFMF-UV同轴式滤光片安装座,250 nm - 450 nm,1/4"-20螺孔,FC/PC接头
¥5,078.62
2 Weeks
FOFMS-UV Support Documentation
FOFMS-UV同轴式滤光片安装座,250 nm - 450 nm,1/4"-20螺孔,SMA接头
¥5,464.53
2 Weeks
FOFMF Support Documentation
FOFMFCustomer Inspired! 同轴式滤光片安装座,450 nm - 20 µm,1/4英寸-20螺孔,FC/PC接头
¥4,972.99
2 Weeks
FOFMS Support Documentation
FOFMSCustomer Inspired! 同轴式滤光片安装座,450 nm - 20 µm,1/4英寸-20螺孔,SMA接头
¥5,366.68
2 Weeks
+1 数量 文档 产品型号 - 公制 单价 现货 / 发货日
FOFMF/M-UV Support Documentation
FOFMF/M-UV同轴式滤光片安装座,250 nm - 450 nm,M6螺孔,FC/PC接头
¥5,078.62
2 Weeks
FOFMS/M-UV Support Documentation
FOFMS/M-UV同轴式滤光片安装座,250 nm - 450 nm,M6螺孔,SMA接头
¥5,464.53
2 Weeks
FOFMF/M Support Documentation
FOFMF/MCustomer Inspired! 同轴式滤光片安装座,450 nm - 20 µm,M6螺孔,FC/PC接头
¥4,972.99
2 Weeks
FOFMS/M Support Documentation
FOFMS/MCustomer Inspired! 同轴式滤光片安装座,450 nm - 20 µm,M6螺孔,SMA接头
¥5,366.68
2 Weeks
Back to Top

可拆卸的滤光片架和空白插条

  • 其他可拆卸的滤光片架用于用于多模光纤的滤光片安装座
  • CFH2-F滤光片架安装座可以安装厚达0.31英寸(8.0 mm)的Ø1英寸滤光片
  • CFH2-B空白滤光片架用于自定义设计
  • 与上面出售的安装座一起使用时不透光

这些可拆卸的滤光片架可轻松与上面所售的用于多模光纤的滤光片安装座兼容。额外的滤光片架可让用户在实验中替换丢失的器件或迅速交换滤光片。滤光片架顶部有两个刻有激光标识的盒子,可让用户标记滤光片架,以便识别已安装的光学元件。一个同轴滤光片安装座最多可安装两个滤光片架。

CFH2-F可安装厚达0.31英寸(8.0 mm)的Ø1英寸光学元件,并且具有SM1螺纹(1.035"-40),可与Thorlabs任何带有SM1螺纹的元件兼容。此外,CFH2-B空白板可以当作手动快门使用,也可经过加工满足您的特殊需求。

+1 数量 文档 产品型号 - 公英制通用 单价 现货 / 发货日
CFH2-F Support Documentation
CFH2-FCustomer Inspired! 额外的滤光片架插条,用于Ø1英寸光学元件,配合CFH2R(/M)使用
¥611.27
Today
CFH2-B Support Documentation
CFH2-BCustomer Inspired! 未钻孔的笼板插条,配合CFH2R(/M)使用
¥556.77
2 Weeks
Back to Top

可调衰减插条

app shot
Click to Enlarge
按下CFH2-V上的调节器可以快速关闭快门。
  • 利用竖直的快门来衰减光
  • 黑色氧化膜可以最大程度地减小背向反射
  • 3/16"-120调节器的衰减分辨率为±0.01 dB(纤芯Ø200 - Ø1000 µm、数值孔径0.22 - 0.50的光纤)
  • 按下调节器,快速关闭孔径(如右图所示)
  • 和上面出售的安装座一起使用时不透光

CFH2-V可调衰减插条兼容上面出售的滤光片安装座,有一个镀有黑色氧化膜的可调快门,以阻挡部分或所有的光。快门从顶端穿过Ø0.54英寸孔径垂直移动,位置受3/16"-120调节器控制。当和纤芯Ø200 - Ø1000 µm、数值孔径0.22 - 0.50的多模光纤一起使用且光束直径最大为0.50英寸时,CFH2-V的衰减分辨率至少为0.01 dB。通过附带的5/64英寸六角扳手,可以对调节器进行精调。按下调节器(如上图所示)可以快速关闭快门;松开调节器,快门回到设定的位置(0.0005英寸范围内)。

+1 数量 文档 产品型号 - 公英制通用 单价 现货 / 发货日
CFH2-V Support Documentation
CFH2-V可调衰减插条,配合CFH2R(/M)和光纤滤光片安装座使用
¥1,807.93
2 Weeks
Back to Top

遮光罩,用于滤光片安装座


图中显示的是安装和不安装FOFM-CV遮光罩的
FOFMF同轴式滤光片安装座。
  • 经过阳极氧化发黑处理的铝质遮光罩,用于同轴式滤光片安装座
  • 内部几何设计便于匹配,形成闭光构造
  • 兼容最高50 mm(1.96英寸)的比色皿(包含塞子)

FOFM-CV是一种遮光罩,兼容上面出售的滤光片安装座,能够保护比色皿,使其不受从支架顶部进入的杂散光和环境光的影响。放置在滤光片安装座上时,安装座和顶盖之间有1.15英寸(29.2 mm)的距离。

该比色皿架兼容最高50 mm(1.96英寸)的比色皿(包括塞子)。请注意,FOFM-CV不兼容CFH2-V衰减插条。

+1 数量 文档 产品型号 - 公英制通用 单价 现货 / 发货日
FOFM-CV Support Documentation
FOFM-CV遮光罩,用于滤光片安装座
¥216.98
2 Weeks